Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
medrxiv; 2021.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2021.11.19.21266579

ABSTRACT

Objective To assess the diagnostic accuracy of three rapid antigen tests (Ag-RDTs) for detecting SARS-CoV-2 infection in the general population. Design Cross-sectional study with follow-up using pseudonymised record linkage. Setting Three Dutch public health service COVID-19 test sites. Participants Consecutively included individuals aged 16 years and older presenting for SARS-CoV-2 testing. Main outcome measures Sensitivity, specificity, positive and negative predictive values of BD-Veritortm System (Becton Dickinson), PanBio (Abbott), and SD-Biosensor (Roche Diagnostics), applying routinely used sampling methods (combined oropharyngeal and nasal [OP-N] or nasopharyngeal [NP] swab), with molecular testing as reference standard. For SDBiosensor, the diagnostic accuracy with OP-N sampling was also assessed. A viral load cutoff ([≥]5.2 log10 SARS-CoV-2 E-gene copies/mL) served as a proxy of infectiousness. Results SARS-CoV-2 prevalence and overall sensitivities with 95% confidence intervals were 188/1441 (13.0%) and 129/188 (68.6% [61.5%-75.2%]) for BD-Veritor, 173/2056 (8.4%) and 119/173 (68.8% [61.3%-75.6%]) for PanBio, and 215/1769 (12.2%) and 160/215 (74.4% [68.0%-80.1%]) for SD-Biosensor with routine sampling, and 164/1689 (9.7%) and 123/164 (75.0% [67.7%-81.4%]) for SD-Biosensor with OP-N sampling. In those symptomatic or asymptomatic at sampling, sensitivities were 72.2%-83.4% and 54.0%-55.9%, respectively. With a viral load cut-off, sensitivities were 125/146 (85.6% [78.9%-90.9%]) for BD-Veritor, 108/121 (89.3% [82.3%-94.2%]) for PanBio, 160/182 (87.9% [82.3%-92.3%]) for SD-Biosensor with routine sampling, and 118/141 (83.7% [76.5%-89.4%]) with OP-N sampling. Specificities were >99%, and positive and negative predictive values >95%, for all tests in most analyses. 61.3% of false negative Ag-RDT participants returned for testing within 14 days (median of 3 days, interquartile range 3) of whom 90.3% tested positive. Conclusions The overall sensitivities of the three Ag-RDTs were 68.6%-75.0%, increasing to at least 85.6% after the viral load cut-off was applied. For SD-Biosensor, the diagnostic accuracy with OP-N and NP sampling was comparable. Over 55% of false negative Ag-RDT participants tested positive during follow-up.


Subject(s)
COVID-19 , Sialic Acid Storage Disease
2.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.12.03.20243311

ABSTRACT

BackgroundAntigen-based point of care tests for identification of SARS-CoV-2 may markedly enhance effectiveness of population-based controlling strategies. Previous studies have demonstrated acceptable sensitivity and high specificity compared to RT-qPCR in symptomatic individuals, but test performance for asymptomatic individuals is unknown. MethodsTest performance of the Panbio COVID-19 Ag Rapid Test (Abbott) was compared to RT-qPCR in a longitudinal cohort study of asymptomatic football players and staff members of professional football clubs. Based on timing of symptoms and prior and subsequent test results, positive RT-qPCR tests were categorized as pre-symptomatic, early or late infection or persistent RNA shedding. Findings2425 tests were performed in 824 individuals, of which 52 (6.3%) were SARS-CoV-2 positive based on RT-qPCR. There were 2406 paired sets from asymptomatic subjects for analysis. Sixteen Panbio tests were inconclusive, for which sensitivity analyses were performed (considering results as either positive or negative or being excluded). Sensitivity of Panbio ranged from 61.76% (95% CI 49.2-73.3) to 69.12% (95% CI: 56.7-79.8) and specificity from 99.53% (95% CI: 99.2-99.8) to 100% (95% CI: 99.8-100). Sensitivity of Panbio to detect subjects with pre-symptomatic/early infection (n= 42) ranged from 81.82% (95% CI: 67.3-91.8) to 90.91% (95% CI: 78.3-97.5) with specificity always above 99%. InterpretationIn asymptomatic subjects the Panbio COVID-19 Ag Rapid Test had sensitivity of 81.82% to 90.91% and specificity above 99% for identifying pre-symptomatic and early SARS-CoV-2 infection. FundingThis study was funded by the executing institutes. The Panbio COVID-19 Ag Rapid Tests were provided by the Ministry of Health, Welfare and Sport (VWS).


Subject(s)
COVID-19 , Infections
SELECTION OF CITATIONS
SEARCH DETAIL